Compaq LP8000-F1 Network Card User Manual


 
5-2 Compaq StorageWorks 64-Bit PCI-To-Fibre Channel Host Bus Adapter User Guide
Compaq Confidential Need to Know Required
Writer: Bill Reitz Project: Compaq StorageWorks 64-Bit PCI-To-Fibre Channel Host Bus Adapter User Guide Comments:
Part Number: AA-RKPDA-TE 173941-001 File Name: F-CH5 FIRMWARE AND DIAGNOSTIC UTILITY.DOCf-ch5 Firmware and Diagnostic Utility.doc
Last
Saved On: 12/28/99 8:56 AM12/21/99 11:52 AM
Functionally, the utility program performs:
Discovery and preliminary testing of the HBA in the system.
Functional testing and operational checks on the HBA.
The use of input and output files to automate the execution of the
diagnostic utility program.
Updating HBA firmware.
NOTE: The diagnostic utility does not operate in the DOS shell under Windows.
i386 System Installation
You must load the software and start the diagnostic utility from the DOS
command line. You can execute I386DNLD.EXE directly from the supplied
software kit or you can load onto your hard drive and execute it from there.
To install the I386DNLD.EXE onto the hard drive:
1. Insert the supplied diskette into your system’s diskette drive.
2. Make a directory and copy the files onto your hard drive, as follows:
C:\md dir_name
C:\copy A:\i386\*.*c:\dir_name
C:\cd dir_name
Where:
Dir_name is the directory where the diagnostic software is stored.
Starting I386DNLD.EXE in an i386 System
To start the I386DNLD.EXE program without any options, type:
From the system disk:
C:\I386DNLD.EXE
From the diskette:
A:/i386DNLD.EXE
The options for I386DNLD.EXE are listed in Table 5-1. The syntax for using
options is: