Compex Systems RAID Network Card User Manual


 
Configuring
3-49
Item
Controller Board Temperature
HDD Temperature
Controller Fan Speed
Power Supply +12V
Power Supply +5V
Power Supply +3.3V
DDR Supply Voltage +2.5V
CPU Core Voltage +1.3V
DDR Termination Power +1.25V
Warning Condition
> 60 Celsius
> 55 Celsius
< 2600 RPM
< 10.8V or > 13.2V
< 4.5V or > 5.5V
< 2.97V or > 3.63V
< 2.25V or > 2.75V
< 1.17V or > 1.43V
< 1.125V or > 1.375V
3.10.3 Hardware Monitor
To view the RAID subsystem controller’s hardware monitor information, move the
mouse cursor to the main menu and click the Hardware Monitor link. The Hard-
ware Information screen appears.
The Hardware Monitor Information provides the temperature, fan speed (chassis
fan) and voltage of the internal RAID subsystem. All items are also unchangeable.
The warning messages will indicate through the LCD, LED and alarm buzzer.