Contec SPI-8452-LLVA Computer Hardware User Manual


 
6. RAID Controller
62
SPI-8451-LLVA, SPI-8452-LLVA, SPI-8451-LVA
Click the Next button to proceed to Rebuild Wizard Step 2 or Cancel button to stop.
Rebuild Wizard Step 2 confirms the Target or “Rebuild” disk by Array # and drive ID.
Click Finish button to initiate physical Rebuild, Back button to review Step 2, or Cancel button to Stop.
A final confirmation window appears as below:
Click “Yes” to initiate Rebuild. To cancel this option, click the No button.
WARNING
Once initiated, Array Rebuild can NOT be halted in order to prevent data errors.
CAUTION
During Array Rebuild, users may continue to access the array and perform normal PC functions
however the array will NOT provide data redundancy until Rebuild is completed. If you choose to
continue using the PC during rebuild, system performance will be slightly degraded and the process
will take longer.
Once Array Rebuild has begun, users are returned to the FastCheck Monitoring window. A progress bar
showing the rebuild progress in percentage will appear at the bottom of the FastCheck Monitoring
window.
CAUTION
When a “spare” unassigned drive is present on the FastTrak100-Lite, a rebuild will automatically be
performed from the remaining working drive.