Crestron eServer™ Ethernet OEM Module
Appendix C: Uploading a SIMPL+ Program
Use the Viewport to upload a SIMPL+ program to the CEN-OEM. Connect the
COM IN port of the eServer to the desired COM port of the PC. Verify
communication parameters and be sure the eServer power pack is connected and
supplying power to the device.
Depress ENTER on the keyboard. If the Viewport responds with ">",
communications is verified.
From Viewport, select File Transport | Send SIMPL+ Program to the
CEN-OEM.
Crestron Viewport
The "Open" dialog box appears. Browse for the desired .csz file and select OK. The
file is transferred to the eServer.
Operations Guide - DOC. 8148 Ethernet OEM Module: eServer™ 35