Crestron electronic IPAC Power Supply User Manual


 
Crestron IPAC Integrated Professional Automation Computer
WARNING: Prior to connecting the IPAC, turn off power at the power supply. Failure
to do so may result in serious personal injury or damage to the device. Restore power
after all connections have been made.
When making connections to the IPAC, note the following:
All terminals accept one 26-16 AWG wire.
Use Crestron
®
power supplies for Crestron equipment.
NOTE: The IPAC can only be powered by either of the 4-position NET connectors.
NET Connectors
Refer to the illustration below when wiring the NET connectors.
24 V
(RED)
GROUND
(BLACK)
24 V
(RED)
GROUND
(BLACK)
Z
(BLUE)
GLA-PWS50
Y
(WHITE)
NETWORK DEVICE
When wiring the NET connectors, consider the following:
Use Crestron Certified Wire such as CRESNET-NP or CRESNET-P. Failure to
do so may incur additional charges if support is required to identify performance
deficiencies because of using improper wire.
Use Crestron power supplies for Crestron equipment.
Provide sufficient power to the system.
CAUTION: Insufficient power can lead to unpredictable results or damage to the
equipment. Please use the Crestron Power Calculator to help calculate how much power
is needed for the system (
www.crestron.com/calculators).
For networks with 20 or more devices, use a Cresnet
®
Hub/Repeater
(CNXHUB) to maintain signal quality.
Installation Guide – DOC. 6696A Integrated Professional Automation Computer: IPAC 3