Datalogic Scanning D8530 Barcode Reader User Manual


 
HOST CONFIGURATION STRINGS
125
POWER SAVE
DESCRIPTION STRING
Illumination System Power Illumination System OFF HAA0
Illumination System ON HAA1
CODE SELECTION
DESCRIPTION STRING
Disable All Symbologies AZA0
Disable All Linear Symbologies AXA0
Disable All 2D Symbologies AYA0
Issue Identical Codes disabled AWB0
enabled AWB1
LINEAR SYMBOLOGIES
UPC/EAN/JAN disabled AEA0
enabled AEA1
Add-on disabled AEB0
enabled AEB1
UPCE extension enabled AEC0
disabled AEC1
Code 39 Standard disabled ABA0
no ckeck digit control ABA1
ckeck digit control without transmission ABA2
ckeck digit control and transmission ABA3
Full ASCII disabled ABB0
enabled ABB1
Code Len Check disabled ABC0
enabled ABC1
Minimum Code Length ABD
d
Maximum Code Length ABE
d
Start/Stop Char TX enabled ABF0
disabled ABF1
Code 32 disabled ABL0
enabled ABL1
d
= a number from the HEX/Numeric Table
d
= a number in the range 001-255