Datalogic Scanning D8530 Barcode Reader User Manual


 
USING POWERSCAN® D8530
7
You can use the aiming system to position the reader from the object (ensure the
reader is about centered over the target). Adjust the distance at which you are
holding the reader (see Figure 2).
If the RS-232 interface h
as been selected, the image will be transferred to the host
PC via XMODEM_1K protocol.
NOTE
Image capturing is not available in Wedge and USB Keyboard
Emulation interfaces and is not compatible with Autoscanning nor
when the Software trigger type is selected.
Up to four different and independent Image Presets can be defined (see page 76).
2.3.1 Basic Configuration Parameters
The Image file formats supported are: TIFF, JPEG (default).
Two resolution options are available: Full Resolution (1280 x 1024 pixels) (default),
and Half Resolution (640 x 512 pixels). The lower resolution setting yields smaller file
sizes, so the transfer time decreases.
For JPEG images it is possible to define the Image Quality level to address tradeoff
between image file size and quality.