The Master scanner is also connected to the Host on the RS232 auxiliary serial
interface.
The External Trigger signal is unique to the system; there is a single reading phase
and a single message from the Master scanner to the Host computer.
It is necessary to bring the External Trigger signal to all the scanners.
The main and auxiliary ports are connected as shown in the figure below.
1
2
3
Auxiliary serial interface
RS485 Main serial interface
External Trigger
Host
DS2200
Slave
DS2200
Slave
DS2200
Master
1
2
3
TX DATA
EXT TRIG
GOOD READ
POWER ON
TX DATA
EXT TRIG
GOOD READ
POWER ON
TX DATA
EXT TRIG
GOOD READ
POWER ON
1
1
Figure 14 – Master/Slave layout
NOTE
The auxiliary serial port of the slave scanners can be used in Local
Echo communication mode to control any single scanner (visualize
data) or to configure it using the WinHost utility or Host Mode
programming procedure.
The termination resistors of the RS485 bus must not be installed.
14