INSTALLATION
2
2.3.2 Main Serial Interface
The signals relative to the following serial interface types are available on the
input/output connector of the DS4600A.
The main serial interface type and its relative parameters (baud rate, data bits,
etc.) are selected via software either using the WinHost utility program or Host
Mode programming. For more details refer to the section "Main Interface Menu"
in the WinHost Help On Line.
Details regarding the connections and use of the main interface selection are given in
the next paragraphs.
RS232 Interface
The serial interface is used in this case for point-to-point connections; it handles
communication with the host computer and allows both transmission of code data
and the configuration of the scanner. This is the default interface.
The following pins of the 25-pin connector are used for RS232 interface connection:
Pin Name Function
2 TX232 transmitted data
3 RX232 received data
4 RTS232 request to send
5 CTS232 clear to send
7 SGND Main signal ground main interface
It is always advisable to use shielded cables. The overall maximum cable length
must be less than 15 m (49.2 ft).
RTS/CTS HARDWARE HANDSHAKING ENABLED
DS4600
A
USER INTERFACE
7
SGND Main
SGND
RTS232
4
DCD
CTS232
5
DTR
RX232
3
TXD
TX232
2
RXD
Earth
Ground
Figure 8 - RS232 Main Interface Connections