HOST CONFIGURATION STRINGS
A
CODE SELECTION (continued)
DESCRIPTION STRING
Codabar disable Codabar family
AD0
Standard no start/stop character equality control
nor transmission
AD111
no start/stop character equality control
but transmission
AD112
start/stop character equality control
but no transmission
AD121
start/stop character equality control
and transmission
AD122
ABC Codabar no start/stop character equality control
but transmission
AD212
Codabar ABC forced concatenation
AD232
code length
AD*
xxxx
start/stop character case in transmission lower case
ADA0
upper case
ADA1
Code 128 disable Code 128 family
AI0
enable Code 128 - control without transmission of check digit
AI11
enable EAN 128 - control without transmission of check digit
AI21
disable
EQ0
Transmit GS before
Code
enable
EQ1
ISBT 128 enable ISBT 128
AI31
code length
AIL
xxxx
Code 93 disable Code 93 family
AK0
enable Code 93 - control without transmission of check digit
AK1
MSI disable the family
AE0
no check
AE1
MOD10 no tx
AE2
MOD10 with tx
AE3
MOD11-MOD10 no tx
AE4
MOD11-MOD10 with tx
AE5
MOD10-MOD10 no tx
AE6
MOD10-MOD10 with tx
AE7
xxxx = ASCII numbers that define the code length where:
• First 2 digits = minimum acceptable code length.
• Second 2 digits = maximum acceptable code length.
The minimum code length must always be less than or equal to the maximum.
The maximum code length for all codes is 99 characters:
EXAMPLES:
0132 = variable length from 1 to 32 digits in the code.
1010 = 10 digit code length only.
177