Datalogic Scanning DX30 Barcode Reader User Manual


 
Enter Configuration Exit and Save Configuration
Ì$+;Î
WEDGE
Ì$
-
NUM LOCK
toggle num lock
ÌFL1kÎ
num lock unchanged
ÌFL0hÎ
This selection is used together with the Alt Mode interface selection for AT or Notebook PCs.
It changes the way the Alt Mode procedure is executed, therefore it should be set as follows:
if your keyboard Num Lock is
normally on use num lock unchanged
if your keyboard Num Lock is
normally off use toggle num lock
In this way the device will execute the Alt Mode procedure correctly for your application.
INTER-CHARACTER DELAY
delay between characters transmitted to Host
ÌCK3Î
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 milliseconds
delay disabled
47