Datalogic Scanning QS6500BT Barcode Reader User Manual


 
Symbologies
6-76 QuickScan
®
QS6500/QS6500 BT
Pharmacode 39 — continued
Code I.D. Selection
The Code I.D. for this symbology consists of one or two user-selectable
ASCII characters. It can be appended previous to or following the trans-
mitted Pharmacode 39 bar code data depending on how this feature is
enabled.
Example: Setting the Pharmacode 39 Code I.D.
To configure this feature:
1. Determine which character(s) you would like to use to represent
the Pharmacode 39 symbology. Reference Appendix A, ASCII Con-
version Chart
to find the corresponding hex values for your chosen
character(s). In this example we’ll set a Code I.D. of “A” to repre-
sent Pharmacode 39. The value from the table corresponding to
‘’A’ is 41. This value will be used in a step to follow.
2. Scan the START bar code
3. Scan the SET PHARMACODE 39 CODE I.D. bar code.
4. Turn to
Appendix B, Alpha-Numeric Pad and scan the bar codes ‘4’
and ‘1’ (the value determined in an earlier step to represent ‘A’).
5. Scan the SET bar code to accept the digits scanned.
6. Turn to the
Data Editing chapter and scan the CODE ID POSI-
TION: BEFORE BAR CODE DATA label.
7. Scan the END bar code to exit Programming Mode.
8. The resulting message string for scanned Pharmacode 39 labels
would appear as follows:
Scanned bar code data: 0123456789123
Resulting message string output: A0123456789123
NOTE
Features configured using the
Data Editing chapter are
universal and will affect all symbologies.