Datalogic Scanning QS6500BT Barcode Reader User Manual


 
Interface Related Features
4-22 QuickScan
®
QS6500/QS6500 BT
RS-232 Interface Features — cont.
ACK NAK Retry Count
START
MODE BARCODE
This feature sets the number of times for the imager
to retry a label transmission under a retry condition.
0 = No retry
1 - 254 = Retry for the specified number of times
255 = Retry forever
To configure this feature, scan the “START” bar code
above to place the unit in Programming Mode, then
the “Set ACK NAK Retry Count,” followed by the dig-
its from the Alphanumeric table in
Appendix B,
Alpha-Numeric Pad
representing your desired retry
count. Accept your selection by scanning the “SET”
bar code below and finally, exit programming mode
by scanning the “END” barcode below
DEFAULT SETTING FOR THIS FEATURE: 03
Set ACK
Nak Retry
Count
SET
END