About Your System 21
E1811 HDD ## Rbld Abrt The specified hard drive has
experienced a rebuild abort.
See "Troubleshooting a Hard
Drive" on page 104. If the problem
persists, see your RAID
documentation.
E1812 HDD ## Removed The specified hard drive has been
removed from the system.
Information only.
E1913 CPU & Firmware
Mismatch
The BMC firmware does not
support the CPU.
Update to the latest BMC
firmware. See the BMC User’s
Guide for more information on
setup and use of BMC.
E1A14 SAS Cable A SAS cable A is missing or bad. Reseat the cable. If the problem
persists, replace the cable. See
"SAS Controller Daughter Card"
on page 56.
E1A15 SAS Cable B SAS cable B is missing or bad. Reseat the cable. If the problem
persists, replace the cable. See
"SAS Controller Daughter Card"
on page 56.
E1A17 Pwr Cable FB Flex bay power cable is missing or
bad.
Reseat the cable. If the problem
persists, replace the cable. See
"SAS Controller Daughter Card"
on page 56.
E1A18 PDB Ctrl Cable Flex bay control signals cable is
missing or bad.
Reseat the cable. If the problem
persists, replace the cable. See
"SAS Controller Daughter Card"
on page 56.
E2010 No Memory No memory is installed in the
system.
Install memory. See "Installing
Memory Modules" on page 65.
E2011 Mem Config Err Memory detected, but is not
configurable. Error detected
during memory configuration.
See "Troubleshooting System
Memory" on page 102.
E2012 Unusable Memory Memory is configured, but not
usable. Memory subsystem failure.
See "Troubleshooting System
Memory" on page 102.
E2013 Shadow BIOS Fail The system BIOS failed to copy its
flash image into memory.
See "Troubleshooting System
Memory" on page 102.
E2014 CMOS Fail CMOS failure. CMOS RAM not
functioning properly.
See "Getting Help" on page 125.
E2015 DMA Controller DMA controller failure. See "Getting Help" on page 125.
Table 1-7. LCD Status Messages (continued)
Code Text Causes Corrective Actions