Dell XK946 Server User Manual


 
About Your System 31
E201F DRAC Config
Dell Remote Assistant
Card (DRAC)
configuration failure.
Check screen for specific
error messages.
Ensure that DRAC cables
and connectors are
properly seated. If problem
persists, see your DRAC
documentation.
E2020 CPU Config
processor configuration
failure.
Check screen for specific
error messages.
E2021 Memory
Population
Incorrect memory
configuration. Memory
population order incorrect.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 139.
E2022 POST Fail
General failure after video. Check screen for specific
error messages.
E2110 MBE Crd #
DIMM ## &
##
One of the DIMMs in the
set implicated by "## &
##" has had a memory
multi-bit error (MBE). If
no memory card is present,
the "Crd #" string is left
out of the message.
See "Troubleshooting
System Memory" on
page 139.
E2111 SBE Log
Disable Crd
# DIMM ##
The system BIOS has
disabled memory single-bit
error (SBE) logging, and
will not resume logging
further SBEs until the
system is rebooted. "##"
represents the DIMM
implicated by the BIOS. If
no memory riser card is
present, the "Crd #" string
is left out of the message.
See "Troubleshooting
System Memory" on
page 139.
Table 1-5. LCD Status Messages
Code Test Causes Corrective Actions