Dell XK946 Server User Manual


 
64 Installing System Components
For 3.5-inch hard drive configurations, the drive blank is keyed to ensure
correct insertion into the drive bay. To install a 3.5-inch drive blank, insert
and rotate in the keyed side of the blank into the drive bay and press evenly
on the other end of the blank until it is fully inserted and latched.
For 2.5-inch hard drive configurations, install the hard drive blank as a 2.5-
inch hard drive carrier:
1
Open the handle on the drive blank.
2
Insert the drive blank into the drive bay until the blank is fully seated.
3
Close the handle to lock the blank in place.
Removing a Hot-Plug Hard Drive
NOTICE: To maintain proper system cooling, all empty hard drive bays must have
drive blanks installed.
1
From the RAID management software, prepare the drive for removal and
wait until the hard drive indicators on the drive carrier signal that the drive
can be removed safely. See your SAS RAID controller documentation for
information about hot-plug drive removal.
If the drive has been online, the green activity/fault indicator will flash as
the drive is powered down. When both drive indicators are off, the drive is
ready for removal.
2
Squeeze the carrier handle to unlatch the carrier from the system.
3
Pull the carrier handle away from the system to extract the carrier. See
Figure 3-4.