Delta Electronics none Network Card User Manual


 
Chapter 3 Connections and Wiring|ASDA-AB Series
3-28 Revision March 2008, Doc. Name: 2007PDD23000011
Be sure to connect a diode when the drive is applied to inductive load.
(Permissible current: 40mA, Instantaneous peak current: max. 100mA)
C5: Wiring of DO signal, for the use of internal
power supply, general load
C6: Wiring of DO signal, for the use of internal
power supply, inductive load
C7: Wiring of DO signal, for the use of external
power supply, general load
C8: Wiring of DO signal, for the use of external
power supply, inductive load
Use a relay or open-collector transistor to input signal.