Diamond Systems RUBY-MM-1612 Computer Hardware User Manual


 
Copyright 2001 Diamond Systems Corp. Ruby-MM-1612 User Manual V1.1 P. 7
Table 4.1: Analog Output Configuration (Header J4)
Range 5 F A
B
U
0-5V: X X X
0-10V: X X
+/-5V: X X X
+/-10V: X X
0-2.5V: X X X
or X X
+/-2.5V: X X X
or X X
An X means that a jumper is installed in that location. Only one half of pin header J4 is shown.
Positions F A B U are repeated for each bank of 8 channels.
Note: Each bank of eight channels (0 - 7 and 8 - 15) can have a different output range setting.
However, all eight channels within a bank will always have the same output range.