19
Operation
7. RF Code Function and
Change Procedure
In the event that the Wall Switch
Remote Control does not work
properly with the receiver due
to interference from additional
wireless signals, this function will
allow the RF code to be changed.
To enable this function, press
9 and 12 together. “COD” will
appear on the display for ve (5)
seconds and the RF code will
change automatically. Repeat
procedure as needed to nd a
code that operates the replace
without interference.
Re-initialization of the Wall Switch
Remote Control will need to take
place with receiver after a new
code has been activated. See
initialization instructions on page 14.
14. Low Battery Indicator
When displayed, the indicator
will signal that the batteries are
low and should be replaced. To
further extend battery life, the
LED backlighting is turned off
when the Low Battery Indicator is
displayed.
Other Functions
6 Hour Sleep Timer
This feature ensures all functions
are turned off six hours after any
last button has been pressed.
To turn this feature on and
off press 9, 11, 10, and 8
sequentially.
When activated, “6 Hr” will display
for 5 seconds while the rest of
the LCD remains blank. For the
duration of the 6 hour delay, all
functions remain working until
the 6 hour time delay runs out.
The Set Temperature and Room
Temperature icons will alternately
display their settings and the “6
Hr” icon display. After 6 hours
have passed and all functions are
turned off, “6 Hr” will ash until
any button is pressed.
!
NOTE: If any button is
pressed while this function is
enabled, the 6 hour timer will
start over for another 6 hour
period.
If / when deactivated, “- Hr” will
display for ve (5) seconds.