Info
Make sure that you remove the lamp unit
by the handle. Do not touch the glass sur-
face of the lamp unit or the inside of the
projector.
To avoid injury to yourself and damage to
the lamp, be sure to carefully follow the
steps below.
Do not loosen other screws except for the
lamp unit cover and lamp unit.
1 Press on the projector or
on the remote control to put the
projector into standby mode.
Wait until the cooling fan stops.
2 Disconnect the power cord.
Unplug the power cord from the AC
socket.
Leave the lamp until it has fully cooled
down (about 1 hour).
3 Remove the lamp unit cover.
Turn the projector over. Loosen the user
service screw (1) that secures the lamp
unit cover. Hold the tab and slide to-
wards the direction of the arrow to re-
move the lamp unit cover (2).
AC socket
STANDBY-ON button
1
2
User service screw
(for lamp unit cover)
Tab
Tab
Removing and Installing the Lamp Unit
Optional
accessory
Lamp unit
AH-57201
Warning!
During projector operation, the lamp unit is very hot. Do not remove the lamp unit from the projector
right after use. The lamp and parts around the lamp will be very hot and may cause burn or injury.
EIP-1500T_E_P53_61.p65 4/28/05, 6:08 PM57