Emerson 4620 Network Router User Manual


 
Accessing HPI Domains Using HPI-B
System Management Interface Based on HPI-B (Centellis 4620) User’s Guide (6806800D85A)
25
The following figure illustrates an example configuration with four domains and three shelves.
Any FRUs available in a shelf are represented as HPI resources together with Resource Data
Records (RDRs) corresponding to that FRU. Whenever a FRU is added to or removed from a
shelf, the corresponding HPI resource/RDR is added/removed from the HPI domain.
4.3.2 Accessing HPI Domains
In order to access an HPI domain, you must open a session via the HPI call
saHpiSessionOpen() and provide as first parameter the domain ID of the corresponding HPI
domain. How to obtain the domain ID is described later within this section about the multishelf
HPI library.
If you want to access several shelves, then you need to open several sessions simultaneously,
one session for each HPI domain which represents a shelf. It is also possible to open several
sessions for one HPI domain/shelf only as well.
When the connection to a shelf is lost, all running HPI calls which access the corresponding
domain return immediately with the error code SA_HPI_ERR_NO_RESPONSE. All open
sessions for the affected domain are automatically closed by the multishelf library. In the
meantime, the library tries to regain access to the shelf. As soon as the connection is
reestablished, the domain is recreated and the application can open another session and
access the domain again. Whenever a domain is created or removed, an HPI event from the
HPI Communication State sensor is generated in the default domain (see Connection State
Sensor on page 30 and HPI Domain Events on page 31).
HPI events are handled domain wide. This means that HPI events from a shelf or FRUs in that
shelf are only visible and can only be received within the session that corresponds to that
domain.
Figure 4-1 Multishelf Library - Representation of Shelves as Domains