System Management Interface Based on HPI-B (Centellis 4620) User’s Guide (6806800D85A)
Using HPI-B HPI Controls for Domain and Shelf Management
34
4.4.1 HPI Controls for Domain and Shelf Management
This refers to the Domain Management Resource and Shelf Management Resource which
were previously explained. Both are Emerson-specific extensions. See Working with the
Multishelf Library on page 24.
4.4.2 IPMI System Boot Options Support
A FRU may have a payload which is capable of booting an operating system (OS). Usually, a
boot firmware, such as BIOS or U-Boot, is started after the payload is powered up or reset. Via
the System Boot Options Control you can set some options for the boot firmware. The boot
firmware will read these settings from the IPMC.
In order to set or get the system boot options, you need to use the HPI Boot Option control.
This control maps the IPMI commands Set System Boot Options and Get System Boot
Options to HPI.
The Boot Option Control is only available for AdvancedTCA front blades and the shelf
manager if the respective IPMC supports the Set System Boot Option IPMI
command. Refer to the Intelligent Platform Management Interface Specification v2.0,
section 28.12 Set System Boot Options Command and 28.13 Get System Boot Options
Command, for further details. Furthermore refer to the respective IPMI Programmer’s
Reference manuals of the respective blades.
Table 4-10 Boot Option RDR
SaHpiRdrT Value
RecordId Assigned by HPI
RdrType SAHPI_CTRL_RDR
Entity The same entity as resource
RdrTypeUnion Defined in next table
IdString MOTHPI_CTRL_NAME_BOOT_OPTION
Table 4-11 Boot Option Control
SaHpiCtrlRecT Value
Num MOTHPI_CTRL_NUM_BOOT_OPTION
Ignore SAHPI_FALSE
OutputType SAHPI_CTRL_OEM
Type SAHPI_CTRL_TYPE_OEM
TypeUnion.Oem.Mid MOTHPI_MANUFACTURER_ID_MOTOROLA
Oem 0