Emerson IPMC7126E Network Cables User Manual


 
IPMC7126E/7616E I/O Module Installation and Use (6806800A45B)
Chapter 3 Programming
24
Vital Product Data (VPD)
To access VPD information for each SBC, access the registers through the I
2
C interface as
follows:
MVME5100 - via the Hawk ASIC; IPMC761’s VPD address is $A4.
MVME5500 - via the Discovery1 device GT64260
MVME6100 - via the Discovery2 device MV64360