12. Specification
12.1 MSL600
Model No. MSL600
Operating principle Ultrasonic sonar
Range 7.0m (23 feet)
Dead band 0.3m (1 foot)
Accuracy +/-35mm (+/- 1.4”)
Resolution 25mm (1”)
Temperature limits
o
C - Sensor -40 to +65 (-40 to 150 degrees F)
Temperature limits
o
C - Control unit -20 to +55 (-4 to 130 degrees F)
Temperature compensation Integral
Power Supply – AC Switch selected 115 or 230Vac
Power Supply – Hz 50/60Hz
Power rating 140VA
Outputs
Relays 2 programmable relays
1 fault relay
Analogue 0/4-20mA
Display LCD 240 x 128 pixels with back light
Communications RS232
Enclosure
IP rating IP66
Material ABS
Dimensions W x H x D 355 x 237 x 95mm (14 x 9.3 x 3.75 INS)
Without compressor housing. See dimensional drawing
for full details.
Programming Via integral membrane keypad
Transducer cleaning method Compressor driven air cleaning