Epson 214D-1 Network Card User Manual


 
Configuration 27
HP289
5. Configuration
The Configuration process enables the Setup Parameters to be
configured, as well as enabling the input signals to be checked.
The configuration process can be entered in one of two ways:
1 By connecting a wire link (or switch) to the rear terminal strip
across terminals 1 and 2
2 By pressing the TOTAL key and while holding, pressing the
RESET key. Both keys must then be held for approximately 6
seconds. This second method of access can be disabled during
the configuration so that it is only possible to enter the
configuration process via the link across terminals 1 and 2.
The key switch actions are during Configuration are as follows:
RUN changes a flashing digit to the next digit.
DISPLAY increments a flashing digit or changes a
parameter selection.
BATCH SET resets a flashing digit to zero.
STOP steps through the configuration sequences.
Note that the arrows in the RUN and DISPLAY key switches indicate
that these switches can be used to change and increment digits
respectively.
In stepping through the configuration sequence, the Parameter
Description is always displayed first, followed by the actual value or
parameter. When a value or parameter can be changed, it is always
shown as flashing and the LED's in the switch panels are lit if that key
switch can be used to change a value.
On first entering the Configuration routine, the display will show:
CAL Setup Program parameters
Batch Enter Batch parameters
Option Options (if installed)
Test Check Input Signals
End Exit to Normal Operation