Epson 214D-1 Network Card User Manual


 
Configuration 31
HP289
5.2 Entering the Batch Parameters
Step Display Description Text
Ref
1 BATCH Set Batch Parameters
OPTION Options (if installed) 5.3
TEST Check Input Signals 5.4
END Exit to normal operation
CAL Setup Program Parameters 5.1
The following steps are displayed when BATCH is selected.
2 BATCH L Maximum Batch Size which can be entered. 3.2
xxxxxx Set to 0 if no limit on batch size.
3 AUTO S Automatic restart feature.
Off Disable
On Enable
xx:xx If enabled, automatically restarts the batch
xx:xx (mins:sec) after the end of the last
batch.
3.2.4
4 START T Slow start time.
xx:xx Time, in minutes:seconds, when Relay 2
will energize once the batch has started.
3.2
5 PREST Prestop Quantity.
xxxx Quantity at which Relay 2 will de-energize
before the end of the batch. (e.g., If the
batch quantity is 100 liters and Prest is 2
liters, relay 2 will de-energize after 98
liters.)
3.2
6 COUNT The Batch Total counts Up or Down.
dn Count down from the batch quantity. 3.2
up Count up from zero.
7 T OUT The Signal Timeout in seconds (Setting to 00
disables this feature.).
3.2.2
8 AOC Automatic Overrun Compensation.
Note that the Signal Timeout must be
greater than 0 (i.e., enabled) for this feature
to work.
3.2.5
En Enable.
Dis Disable.