Extron electronic MAV Switch User Manual


 
4-3MAV Series Switchers • Programmer’s Guide
RAM Test Failed
ROM Checksum Failed
EEPROM Reset (Presets/Attenuators)
Serial EEPROM Reset (Current Settings)
Invalid Jumpers
If an error occurs during powerup, the switcher initiates one or more of the
messages listed above.
All Configuration Memory Cleared
The memory cleared message is initiated by the switcher when a system reset has
occurred. See System reset to factory defaults in chapter 3.
The switcher does not expect a response from the host, but, for example, the host
program might request a new status.
Switcher Error Responses
When the switcher receives an SIS command and determines that it is valid, it
performs the command and sends a response to the host device. If the switcher is
unable to perform the command because the command is invalid or contains
invalid parameters, the switcher returns an error response to the host. The error
response codes are:
E01 — Invalid input channel number (too large)
E10 — Invalid command
E11 — Invalid preset number (too large)
E12 — Invalid output number (too large)
E13 — Invalid value (out of range)
E14 — Illegal command for this configuration
E17 — Timeout (only caused by direct write of global presets)
Using the Command/Response Table
The command/response table begins below. Lower case letters are acceptable in
the command field only where indicated. Symbols are used throughout the table to
represent variables in the command/response fields. Command and response
examples are shown throughout the table.
ASCII to HEX Conversion Table
Space