Extron electronic MLC 104 Plus Series Switch User Manual


 
MLC 104 Plus Series • Software Setup
Software Setup, cont’d
3-22
The Button Operations User Defined tab allows users to add
button functionality that is not predened by entering ASCII
strings or Extron Simple Instruction Set (SIS
) commands in
the Command eld and moving those commands to the Press
window or the Release window. The User Dened tab is only
functional with serial ports.
For a listing of ASCII codes, click View > View ASCII Chart.
To add a user defined command:
1. Select a front panel button.
2. Click the Button Operations User Defined tab.
3. Expand a serial port.
4. Click User Defined Command.
5. Enter your desired ASCII command string in the
Command window.
6. Drag the user dened command to the Press window or
the Release window.
- or -
Use the green right arrow buttons () to move the user
dened command to the Press window or the Release
window.