MTP 15HD A Series • Installation
VersaTools
®
MTP 15HD A Series, cont’d
4. Circuit overloading — Consideration should be given to
the connection of the equipment to the supply circuit and
the effect that overloading of the circuits might have on
overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be
used when addressing this concern.
5. Reliable earthing (grounding) — Reliable earthing of
rack-mounted equipment should be maintained.
Particular attention should be given to supply connections
other than direct connections to the branch circuit (such as
the use of power strips).
Rack mounting instructions
For optional rack mounting, mount the MTP on any of the
following rack shelves:
RSF 123 VersaTools
®
19" 1U rack shelf kit (part #60-190-20)
(figure 1)
RSB 123 VersaTools 19" basic 1U rack shelf (part #60-604-21)
RSU 126 6" deep 1U rack shelf kit (part #60-190-10)
RSB 126 6" deep basic 1U rack shelf (part #60-604-11)
RSU 129 standard 9.5" universal 1U rack shelf kit
(part #60-190-01) (figure 2)
RSB 129 basic 9.5" universal 1U rack shelf (part #60-604-02)
(2) 4-40 x 3/16" Screws
Use 2 mounting holes on
opposite corners.
VersaTools Basic
Rack Shelf
Quarter Rack Width False
Faceplate
M
TP T VGA RS
M
T
P
T
V
G
A
R
S
M
T
P
T
V
G
A
R
S
Figure 1 — Mounting the MTP on a VersaTools shelf
End Unit Receiver DIP Switch
Set the receiver’s rear panel End Unit DIP switch up only if
either of the following is true:
The receiver being configured is the only receiver
connected to the transmitter.
The receiver being configured is the last receiver in a
daisy-chained system.
If one or more receivers are connected to the Buffered Output
RJ-45 connector of the receiver being configured, set that
receiver’s End Unit switch down.
Installation
CAUTION
Installation and service must be performed by
authorized personnel only.
The 1U high, quarter rack width, MTP transmitter and all
receiver models can be mounted on a rack shelf, to a rack
without a shelf, under a desk or tabletop, or on a projector
bracket.
Rack mounting
UL guidelines
The following Underwriters Laboratories (UL) guidelines
pertain to the installation of the MTP transmitter or receiver into
a rack.
1. Elevated operating ambient temperature — If the
equipment is installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack
environment may be greater than room ambient.
Therefore, consider installing the equipment in an
environment compatible with the maximum 122° F (50° C)
ambient temperature (Tma) specified by Extron.
2. Reduced air flow — Installation of the equipment in a
rack should be such that the amount of air flow required
for safe operation of the equipment is not compromised.
3. Mechanical loading — Mounting of the equipment in the
rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
VersaTools
®
MTP 15HD A Series • Installation 76 VersaTools
®
MTP 15HD A Series • Installation