SW8/12 VGA Ars • Control
Error responses
When the switcher receives a valid command, it executes the command and sends
a response to the host device. If the unit is unable to execute the command because
the command contains invalid parameters, it returns an error response to the host.
Error response codes are:
E01—Invalidinputchannelnumber(outofrange)
E06—Invalidinputchannelchange(auto-switchmodeactive)
E09—Invalidfunction(mode)parameter
E10—Invalidcommand
E13 — Invalid value (out of range)
Timeout
Apauseof10secondsorlongerbetweencommandASCIIcharactersresultsina
timeout. The command operation is aborted with no other indication.
Using the command/response table
Thecommand/responsetableisonthefollowingpages.Lowercaselettersare
allowed in the command field only as indicated. Symbols are used throughout
thetabletorepresentvariablesinthecommand/responseelds.Commandand
responseexamplesareshownthroughoutthetable.TheASCIItoHEXconversion
tablebelowisforusewiththecommand/responsetable.
ASCII to HEX Conversion Table
Space
Figure 3-1 ASCII-to-HEX conversion table
Symbol definitions
]
=CR/LF(carriagereturn/linefeed)
}
= Carriage return (no line feed)
= Space character
X!
=Inputnumber SW8=0through8
SW12=0through12
0=outputmute
X@
=Indicatessignalpresence 0=signalnotpresent
1 = signal is present
X#
=On/offstatus 0=off
1 = on
X$
=Volumevalue/range 0-100
X%
= Switch mode 1 = normal mode
2 = auto switch mode