Level
Cutout for
Signal Cable
Access
Marker for
Pilot Hole
USFM 100
Base Plate
Mounting
Holes
Signal Cables
Exiting from
Cutout
Figure 2. Wall Mounting Features
c. If the cables are to be run behind the wall to the USFM 100 location, mark the cutout area on the wall large
enough for signal cables (see figure 2).
d. Remove the base plate and set it aside. Cut out the marked area for cable access.
For drywall with wood studs
i. Drill ¼ inch pilot holes at the marked stud locations.
ii. Align the base plate mounting holes over the pilot holes and lightly secure with 5/16 inch lag screws and
washers.
NOTE: If using toggle screws for assembly, follow the installation method (steps A-D) shown in figure 3.
A. Grasp plastic handle, collapse
toggle and insert into wall.
B. Slide plastic washer down
into pilot hole.
C. Cut off plastic handle close
to wall.
D. Hand screw in pan head bolt
until 1/8 inch gap remains.
Figure 3. Steps for Toggle Assembly Installation
iii. Verify level and position, and fully tighten down all the screws to secure the plate flush to the wall.
For drywall with steel studs
i. Drill a ½ inch (13 mm) hole through the stud at each of the locations (four recommended).
ii. Insert the supplied toggles through the studs and lightly secure the plate using the four supplied
(¼-20 x 2 inch) bolts and washers.
iii. Verify level and position, and fully tighten down all the bolts to secure the plate flush to the wall.
2. Mount the Switcher
a. Place the mounting plate flat on the switcher base with the two small raised tabs on top, and the small
securing tab over the front panel. Align the two mounting holes in the switcher base with the corresponding
holes on the mounting plate. Secure the plate to the switcher using the two 4-40 x ¼ inch pan head screws.
b. Secure the mounting plate (and switcher) to the base plate by aligning the two small tabs on the back of the
mounting plate over the corresponding tabs on the base plate (see figure 4, inset). Slide the mounting plate
(and switcher) down into place. Secure it to the base plate by passing a 6-32x¼ inch screw up through the