3-13. Overall Frequency Response Adjustment
Set the controls under the same condition as 3.12 except the DOLBY switch. (The switch should be turned on.)
Apply a 400 Hz, -35 dBV (18 mV) signal to the INPUT 1 and 2 phone jacks.
Record the signal, rewind and playback the recorded section of the tape and memorize the output level at TAPE
OUT 1 ~ 4.
Next, apply 6 kHz & 12 kHz, -35 dBV (18 mV) signals to the INPUT 1 and 2 phone jacks.
Record the signal, rewind and playback the recorded section of the tape.
Check if the 6 kHz / 12 kHz output level at TAPE OUT 1 ~ 4 is within ± 2 dB comparing to the 400 Hz output level.
If the AC volt meter reading is not within the above specification, adjust the pot R133 ~ 433 (220 kΩ) on the R/P
AMP PCB assy so that the recording level at 6 kHz will be within the specification.
1)
2)
3)
4)
5)
6)
3-14. T.H.D. Measurement
Connect a distortion meter, 400 Hz HPF and 30 kHz LPF to TAPE OUT 1 ~ 4 and set the controls under the same
condition as 3-12.
Record a 1 kHz, -10 dBV (0.3 V) sine wave signal.
Playback the recorded part and check if the distortion level is less than 2 %.
1)
2)
3)
3-15. Erasure Measurement
Connect a 1 kHz bandpass filter and AC volt meter to TAPE OUT 1 ~ 4 and set the controls under the same
condition as 3-12.
Record a 1 kHz, 0 dBV (1 V) sine wave signal which is 10 dB higher than the reference recording level on a blank
tape.
Rewind the tape to the start point of recording and advance it by a short length. Then, record again without
applying the signal on the remaining part.
Rewind the tape to the start point again and play it back. Check if the level ratio between the playback level and no-
signal section (erased part) is 67 dB or more.
1)
2)
3)
4)
3-16. Cross Erasure Measurement
Set the controls as follow.
Trim knob: At minimum
Input fader: Standard position (At 8 ± 1)
Dolby B noise reduction on/off switch: OFF
Input a 100 kHz, -10 dBV signal to the INPUT 1 and 2 phone jacks and record the signal on all tracks.
Rewind the tape to the start point of recording. Then, erase the 10 kHz signal on the track and check if the level
difference at the corresponding track indicated below is within 1 dB.
Tracks to be measured Track (s) to be erased
12
2 1 and 3
3 2 and 4
43
If the level goes down by more than 1 dB, check the tape running path again.