FBR12 SERIES TO
BE DISCONTINIED
Item
High Sensitive Type
Standard (Gold-overlay silver-nickel)
-P type (Gold-overlay silver-palladium)
Contact Arrangement 2 form C (DPDT)
Material Gold-overlay silver-nickel Gold-overlay silver-palladium
Style Bifurcated
Resistance (initial) Maximum 100 m (at 0.1 A 6 VDC)
Rating (resistive) 0.3 A 125 VAC or 1 A 30 VDC
Maximum Carrying Current 2 A (at 20°C)
Maximum Switching Power 62.5 VA or 30 W
Max. Switching Voltage*
1
250 VAC or 220 VDC
Maximum Switching Current 2 A
Minimum Switching Load*
2
10m VDC - 10µ A
Capacitance Approximately 1.0 pF (between open contacts, adjacent contacts )
(at 10 kHz) Approximately1.0 pF (between coil and contacts)
Coil Nominal power (at 20°C) Approximately 50mW
Operate power (at 20°C) Approximately 40m W
Operating Temperature –40°C to +70°C (no frost) (refer to the CHARACTERISTIC DATA)
Operating Humidity 45 to 85%RH
Time Value Operate (at nominal voltage) Maximum 5 msec.
Release (at nominal voltage) Maximum 5 msec.
Insulation Resistance (initial) Minimum 1000 M (at 500 VDC)
Dielectric
between open contacts
750 VAC
Strength
adjacent contacts
1 minute
between coil and contacts
1,500 VAC 1 minutes
Surge
between open
1,500 V
Strength
contacts,
10 × 700 µs
adjacent contacts
between coil and contacts
2,500 V
2 × 10 µs
Life Mechanical 1 x 10
8
operations minimum
Electrical DC 2 × 10
5
operations minimum 5 × 10
5
operations minimum
(at contact rating)
AC 1 × 10
5
operations minimum 200 × 10
3
operations minimum
Other Vibration Misoperation 10 to 55 Hz (double amplitude of 3.3` mm)
Resistance
Endurance 10 to 55 Hz (double amplitude of 5.0 mm)
Shock Misoperation 500 m/s
2
(11±
1
ms)
Resistance
Endurance 1,000 m/s
2
( 6 ±
1
ms)
Weight Approx. 1.9 g
SPECIFICATIONS
*
1
If the switching voltage exceeds the rated contact voltage, reduce the current. The current values vary according to the
type of load.
*
2
Values when switching a resistive load at normal room temperature and humidity and in a clean environment.
The minimum switching load varies with the switching frequency and operation environment.