9. Raise the CPU Module insertion/extraction tool on the CPU Module side until the
tool is standing upright, perpendicular to the ground.
The CPU module and CMU connectors are coupled, and the new CPU module is
mounted.
FIGURE 6-25 Mounting the CPU Module
Caution – Each CPU Module has two CMU guide locks. Perform the work in such a way
that both guide locks are correctly set. Raise the insertion/extraction tool until it touches the
stopper and is perpendicular to the ground. The connector is securely engaged when the
insertion/extraction tool is raised vertically and it comes into contact with the stopper. Do not
forcibly raise the insertion/extraction tool further.
10. Move the CPU module insertion/extraction tool in the opposite way of Step 8 to
remove the tool.
Caution – After using the CPU module insertion/extraction tool, be sure to return it to the
storage location in the server.