Fujitsu M8000 Server User Manual


 
25-12 SPARC Enterprise M8000/M9000 Servers Service Manual October 2012
13. Check the updated OpenBoot PROM version.
In the following output sample, the OpenBoot PROM version of XCP 1100 is 02.17.0000.
14. Power off the target domain.
15. By using XSCF, replace the CPU with the new CPU for upgrade.
a. Execute the replacefru(8) command and select "CMU/IOU" from the
maintenance menu.
b. Based on Section 6.2, “Active Replacement and Hot Replacement” on page 6-5,
perform the replacement operation according to the instructions displayed in the
maintenance menu.
For details on how to replace CPU module (CPUM) to CMU, see Section 6.4.2, “CPU
Module Replacement” on page 6-25.
Caution – To the CMU on which the upgraded CPU mounted, do not fail to execute the
diagnostic test which is provided in the maintenance menu of the replacefru(8)
command.
16. Confirm that the mounted CPU module has been recognized by the server, and the
error indicator asterisk (*) is not displayed.
17. Use the showlogs error -v command and the showstatus(8) command, to
confirm that no errors occurred.
XSCF> version -c cmu -v
DomainID 00 : 02.03.0000
DomainID 01 : 02.03.0000
DomainID 02 : 02.17.0000
DomainID 03 : 02.17.0000
...
DomainID 15 : 02.03.0000
XSB#00-0 : 02.03.0000 (Current), 02.02.0000 (Reserve)
XSB#00-1 : 02.03.0000 (Current), 02.02.0000 (Reserve)
XSB#00-2 : 02.03.0000 (Current), 02.02.0000 (Reserve)
XSB#00-3 : 02.03.0000 (Current), 02.02.0000 (Reserve)
XSB#01-0 : 02.03.0000 (Reserve), 02.17.0000 (Current)
XSB#01-1 : 02.03.0000 (Reserve), 02.17.0000 (Current)
XSB#01-2 : 02.03.0000 (Reserve), 02.17.0000 (Current)
XSB#01-3 : 02.03.0000 (Reserve), 02.17.0000 (Current)
...
XSCF> poweroff -d domain_id
XSCF> replacefru
XSCF> showhardconf -M