4.1 Mounting Requirements
C141-E163 4-3
4.1.2 Mounting
The permissible orientations of the IDD are shown in Figure 4.2, and the tolerance of the angle is ±5°
from the horizontal plane.
(a) Horizontal –1 (b) Horizontal –2 (c) Vertical –1
(d) Vertical –2 (e) Upright mounting –1 (f) Upright mounting –2
Figure 4.2 IDD orientations
4.1.3 Notes on mounting
(1) Mounting frame structure
Special attention must be given to mount the IDD disk enclosure (DE) as follows.
a) Use the frame with an embossed structure, or the like. Mount the IDD with making a gap of
2.5 mm or more between the IDD and the frame of the system.
b) As shown in Figure 4.3, the inward projection of the screw from the IDD frame wall at the
corner must be 5.0 mm or less.
c) Tightening torque of screw must be secured with 0.59N·m (6kgf·cm) ±12%.
d) Impact caused by the electric driver must be within the device specifications.
Direction of gravity