Fujitsu MPG3204AH Computer Drive User Manual


 
C141-E112-01EN
5 - 60
At command issuance (I-O registers setting contents)
1F7
H
(CM) 11110100
1F6
H
(DH)
×××
DV xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
xx
xx
xx
xx
xx
At command completion (I-O registers setting contents)
1F7
H
(ST) Status information
1F6
H
(DH)
×××
DV xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
xx
xx
xx
xx
Error information
(33) SECURITY FREEZE LOCK (F5h)
This command puts the device into FROZEN MODE. The following commands used to change
the lock function return the Aborted Command error if the device is in FROZEN MODE.
SECURITY SET PASSWORD
SECURITY UNLOCK
SECURITY DISABLE PASSWORD
SECURITY ERASE PREPARE
SECURITY ERASE UNIT
FROZEN MODE is canceled when the power is turned off. If this command is reissued in
FROZEN MODE, the command is completed and FROZEN MODE remains unchanged.
Issuing this command during LOCKED MODE returns the Aborted Command error.
The following medium access commands return the Aborted Command error when the device is
in LOCKED MODE: