12 ServerView Remote Management Frontend
Configuration Installation and configuration
– SSH access to the iRMC/ iRMC S2:
In the ServerView [server-name] window for PRIMERGY servers with
iRMC/ iRMC S2, the iRMC SSH button for SSH access to the
iRMC/ iRMC S2 is displayed (see figure 5 on page 22).
Default value: The iRMC SSH button is displayed.
– Console redirection (SOL) and power management for PRIMERGY
servers with iRMC/ iRMC S2:
The corresponding button (iRMC Power Management) is displayed in the
ServerView [server-name] window (see figure 5 on page 22).
Default value: The iRMC Power Management button for console redirection
(SOL) and power management is not displayed.
Configuring settings in the “Features” folder
You can activate or deactivate the individual features (multisession support,
display of certain buttons) by creating or deleting the corresponding text files in
the Features folder. The content of the text files is irrelevant, i.e. the files can be
empty.
The following fixed names must be used for the text files:
MultiSessionBMC
Multisession support for BMC/ iRMC/ iRMC S2 power management and
console redirection is activated.
SSHiRMC
The button for SSH access to iRMC/ iRMC S2 is displayed for
PRIMERGY servers with iRMC/ iRMC S2.
SOLiRMC
The button for console redirection (SOL) and power management is
displayed for PRIMERGY servers with iRMC/ iRMC S2.
I Please note:
– The file names are not case-sensitive.
– The file names must not have any name suffix (.txt).