GE IC5008 Personal Computer User Manual


 
3-6 Intelligence Panel PC User’s Manual – August 2003 GFK-2023C
3
Hazardous Locations Installation
Warning
When installing the unit in an environment where there is the
potential for flammable gases, vapors or liquids to be present the
power cable must be secured to the unit using the enclosed cable
clamp kit. In addition, the power cable must have the male plug
removed and be permanently hard-wired to the AC source.
Mounting holes for
cable clamp
Power connector
Figure 3-4. Cable Clamp Mounting for Power Cable
Power Cable Installation Instructions
1. Attach clamp to power plug with the two screws provided.
2. Plug power cable into power connector on unit.
3. Securely attach the power plug and clamp assembly to the chassis at the two screw
holes provided to the left and right of the plug.