39HP StorageWorks 1000ux/1900ux/2300ux Optical Jukebox User’s Guide
Setting an operating configuration
READY > ADMIN* > CONFIG*
To set an operating configuration:
1. With READY displaying on the control panel, press NEXT until ADMIN*
displays.
2. Enter the administration password (see “Entering the administration menu
password” on page 34).
3. TEST* displays. Press NEXT until CONFIG* displays and then press
ENTER.
4. Press NEXT or PREV until the name of the configuration you want to set
displays and then press ENTER.
If the configuration has multiple settings, the current setting flashes. Proceed
to step 5. Otherwise, the configuration is set and a confirmation message
displays.
SECURE MAIL
OUT/IN
Toggles between OUT and IN. Determines the
orientation of the mailslot when the SECURE
configuration is set to IN. When set to OUT, the mailslot
remains in its normal orientation. When set to IN, the
mailslot rotates in, making it inaccessible.
OUT
POWER SECURE
ON/OFF
Toggles between ON and OFF. The ON configuration
retains your selection of the SECURE MS configuration
through power cycling (or power outage). The OFF
configuration allows the jukebox to return to the default
setting of this configuration after a power cycling.
POWER
SECURE OFF
REP RECOVERED
ON/OFF
Toggles between ON and OFF. When set to ON,
recovered errors are reported; when set to OFF,
recovered errors are not reported.
REP
RECOVERED
ON
CONF40 ON/OFF
Caution: Changing this configuration may
result in a service call. Used by service
personnel only.
NA
Configuration Name Description Default