HP (Hewlett-Packard) 220 All in One Printer User Manual


 
ALT
Media-Sensor
Calibration
7Ć9 CalibrationsC3187Ć90000
MediaĆSensor Calibration
The mediaĆsensor calibration measures the position of the mediaĆsensor levers with respect
to the drive roller. A value is stored in the EEROM when the procedure is completed.
Perform the mediaĆsensor calibration whenever:
The EEROM is cleared
The main PCA is replaced
The media sensor is removed or replaced
The leading and trailing margins of a plot are greater than 17 mm (0.67 in).
To calibrate the media sensor, perform the following procedure:
, Enter service mode page 7Ć2.
. Hold down the
ALT key and press Media Calibration.
Any loaded media is ejected by the plotter.
A When the
Load Media LED begins to flash, load a sheet of media in landscape orientation.
Th adig z a g ha a ba h h agi a ad
a i. O h h i add, i i jd agai.
4 When the
Load Media LED begins to flash again, load the same sheet in portrait
orientation.
Agai, h adig z a g ha a ba h h agi a
ad a i. O h h i add, i i jd agai, ad h
Ready
L igh z.