HP (Hewlett-Packard) 2995 Power Supply User Manual


 
7
Step 2. Choose a Suitable Location
The installation site directly impacts the functionality and lifespan of the control.
Avoid areas where surrounding air temperature exceeds 40
O
C (direct
sunlight or near heating equipment or inside a panel without a cooling fan.
Avoid locations where the front panel dial and switch may be bumped and
accidentally turned on/off or damaged.
Avoid environments with corrosive gas.
Avoid locations near radioactive matter or flammable material.
Avoid locations near equipment that generate electromagnetic interference
(soldering or power machinery).
Avoid mounting the control to a surface that vibrates.
Step 3 – Mount the
Control
Prepare the mounting surface by
drilling four holes with their
centers located as shown in
Figure 3. If #10 screws are to be
used for mounting, then use a #6
(.204) clearance drill. If #10-32
machine screws are to be used
for mounting, then use a #20
(.161) tap drill. After the
mounting surface has been
prepared, mount the control with
screws through the four
mounting brackets (already
attached to back of control
enclosure).
Figure 3 - Mounting
Dimensions