The HP 60 Modular Smart Array enclosure is a 2U Serial Attach SCSI (SAS) disk drive storage enclosure supporting 3.5 inch SAS,
Serial ATA (SATA) and SAS Midline (MDL) drives. This enclosure delivers industry-leading data performance, availability, storage
density, and upgradeability to meet customers' demanding and growing storage needs. This enclosure is designed to support 3.5
inch Universal SAS, SATA or SAS MDL hard drive form factors. The MSA60 enclosure supports direct attach storage (DAS) to HP
ProLiant and HP Integrity Servers. The MSA60 supports the cascading of shelves in a 1+3 configuration to allow a maximum of 48
drives in an 8U configuration behind each of the two external ports on the HP Smart Array P800, the HP Smart Array E500, HP
Smart Array P411 or the HP Smart Array P812 Controllers for a total of 96 drives in 8 enclosures (this single controller port
incorporates four lanes for a total max throughput of 12Gb/s for SAS). On HP ProLiant servers Dual Domain support is available for
the HP Smart Array P800 attached to a MSA60 with the addition of the HP Dual Domain I/O Module Option (AG779A). (Single
initiator environment only). (
NOTE:
NOTE:NOTE:
NOTE:
Smart Array P411 and P812 Controllers are supported on ProLiant servers only
).
The MSA60 also supports the HP Smart Array P600 and the HP Smart Array P212 Controllers. Behind the single external port on the
HP Smart Array P600 or the P212 Controllers 1+3 cascading allows a maximum of 48 drives in an 8U configuration. (
NOTE:
NOTE:NOTE:
NOTE:
Smart Array P212 Controller is supported on ProLiant servers only
).
For HP-UX and Open VMS environments on HP Integrity Servers the MSA60 supports the HP (AH303A) SC44Ge Host Bus Adapter
with the addition of the HP Dual Domain I/O Module Option (AG779A). Behind the single external port on the HP (AH303A)
SC44Ge Host Bus Adapter 1+3 cascading allows a maximum of 48 drives in an 8U configuration. The HP (AH303A) SC44Ge Host
Bust Adapter will only support HP-UX and Open VMS environments and will be available on all rack mounted HP Integrity Servers
with PCIe slots.
The addition of the I/O Module with the HP SC44Ge Host Bus Adapter adds support for Multi Initiator JBOD Clusters. It will support
HP-UX and Open VMS on selected HP Integrity servers only. The MSA60 with the I/O Module and the HP SC44Ge Host Bus Adapter
will not support ProLiant servers. Multi Initiator JBOD clusters are supported with dual port SAS drives only.
Support for HP Serviceguard software on HP-UX with HP-UX 11iv2/11iv3 only.
HP Serviceguard monitors the health of each node and rapidly responds to failures in a way that minimizes or eliminates application
downtime.
NOTE:
NOTE:NOTE:
NOTE:
HP Integrity servers that are supported:
rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e cards)
What's New
What's NewWhat's New
What's New
Introducing support for the new HP Smart Array Controller for the MSA60 with ProLiant servers
HP Smart Array P812 Controller/1G Flash Backed Cache Controller
Introducing support for new drives
HP 2 TB 3G SATA 7.2K LFF (3.5 inch) MDL HDD
HP 1 TB 6G SAS 7.2K LFF (3.5 inch) DP MDL HDD
HP 2 TB 6G SAS 7.2K LFF (3.5 inch) DP MDL HDD
QuickSpecs
HP 60 Modular Smart Array
HP 60 Modular Smart ArrayHP 60 Modular Smart Array
HP 60 Modular Smart Array
Overview
DA - 12627 North America — Version 37 — June 8, 2011