HP (Hewlett-Packard) 418408-B21 Computer Drive User Manual


 
LED Indicators for HDDs
LED Indicators for HDDsLED Indicators for HDDs
LED Indicators for HDDs
Online (bottom)
Drive Failure/ID (top)
LED Indicators on Front
LED Indicators on FrontLED Indicators on Front
LED Indicators on Front
Panel
PanelPanel
Panel
Heartbeat LED
Fault LED
UID button/LED
LED Indicators on Rear
LED Indicators on RearLED Indicators on Rear
LED Indicators on Rear
Panel
PanelPanel
Panel
I/O Module LED
UID button/LED
Heartbeat LED
Fault LED
Power On/Standby button/system power LED
Power supply LED
Host Interface
Host InterfaceHost Interface
Host Interface
4 x wide SAS 3 Gb/s ports
Maximum Number of
Maximum Number ofMaximum Number of
Maximum Number of
Drives
DrivesDrives
Drives
Up to 12 (twelve), 3.5 inch SAS, SATA or SAS MDL drives
Temperature Range
Temperature RangeTemperature Range
Temperature Range
Operating
OperatingOperating
Operating
50° to 95° F (10° to 35° C)
Shipping
ShippingShipping
Shipping
-40° to 150° F (-40° to 66° C)
NOTE:
NOTE: NOTE:
NOTE:
Rated 1°C per 1000 feet of elevation to 10,000 ft.
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
Operating
OperatingOperating
Operating
10% to 90%
Non-operating
Non-operatingNon-operating
Non-operating
Up to 95%
Input Power
Input PowerInput Power
Input Power
Requirements
RequirementsRequirements
Requirements
Rated Input Voltage
Rated Input VoltageRated Input Voltage
Rated Input Voltage
100 to 240 VAC
Rated Input Frequency
Rated Input FrequencyRated Input Frequency
Rated Input Frequency
50 to 60 Hz
Rated Input Current
Rated Input CurrentRated Input Current
Rated Input Current
3.9A at110 VAC typical, 6A Maximum
Input Power
Input PowerInput Power
Input Power
(max)
345 W
Heat Dissipation
Heat DissipationHeat Dissipation
Heat Dissipation
(maximum)
1175 Btu/hr*
* Input Power and Heat Dissipation specifications are maximum values and apply to worst-case
conditions at full rated power supply load. The power/heat dissipation for your installation will vary
depending on the equipment configuration.
RAID Support
RAID SupportRAID Support
RAID Support
See Qucikspecs for Smart Array Controllers P600, P800, E500, P212, P411 & P812
http://h18004.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.html
Upgradeable Firmware
Upgradeable FirmwareUpgradeable Firmware
Upgradeable Firmware
Yes, Offline only. Firmware updates available through hp.com
Disk Drives and
Disk Drives andDisk Drives and
Disk Drives and
Enclosure Protocol
Enclosure ProtocolEnclosure Protocol
Enclosure Protocol
Support
SupportSupport
Support
HP 3.5 inch SAS 3 Gb/s
I/O Module
I/O ModuleI/O Module
I/O Module
Connector Type
Connector TypeConnector Type
Connector Type
IPass (mini-SAS)
Number of Ports
Number of PortsNumber of Ports
Number of Ports
Two (one IN, other is OUT)
MSA60 Enclosure
MSA60 EnclosureMSA60 Enclosure
MSA60 Enclosure
2U Rack Form Factor
2U Rack Form Factor2U Rack Form Factor
2U Rack Form Factor
Dimensions
DimensionsDimensions
Dimensions
(HxWxD)
3.47 x 17.64 x 23.25 in (8.8 x 44.8 x 59 cm)
Weight
WeightWeight
Weight
(base unit)
34 lb (15.4 kg)
Weight
WeightWeight
Weight
(with all drives)
54 lb (24.6 kg)
QuickSpecs
HP 60 Modular Smart Array
HP 60 Modular Smart ArrayHP 60 Modular Smart Array
HP 60 Modular Smart Array
Technical Specifications
DA - 12627 North America — Version 37 — June 8, 2011