HP (Hewlett-Packard) 418408-B21 Computer Drive User Manual


 
Step 2: Array Controllers
Step 2: Array ControllersStep 2: Array Controllers
Step 2: Array Controllers
Description
DescriptionDescription
Description
Part Number
Part NumberPart Number
Part Number
Smart Array Controllers
Smart Array ControllersSmart Array Controllers
Smart Array Controllers
Supported
SupportedSupported
Supported
(Single Domain)
HP ProLiant Servers
HP ProLiant ServersHP ProLiant Servers
HP ProLiant Servers
HP Smart Array P800 controller
381513-B21
HP Smart Array E500 controller
435129-B21
HP Smart Array P600/256 BBWC Controller
337972-B21
HP Smart Array P812 Controller/ 1G Flash Backed Cache Controller
487204-B21
HP Smart Array P411/256MB Controller
462830-B21
HP Smart Array P411/512MB BBWC
462832-B21
HP Smart Array P411/1G FBWC Controller
572531-B21
HP Smart Array P212/256MB Controller
462834-B21
HP Integrity Servers
HP Integrity ServersHP Integrity Servers
HP Integrity Servers
HP Smart Array P800 controller
AD335A
HP Smart Array E500 controller
AH226A
HP Smart Array P600/256 BBWC Controller
337972-B21
NOTE:
NOTE: NOTE:
NOTE:
The HP Smart Array P800 supports the cascading of shelves in a 1+3
configuration to allow a maximum of 48 drives in an 8U configuration behind or the
HP Smart Array P800 controller for a total of 96 drives on the two external ports.
NOTE:
NOTE: NOTE:
NOTE:
Dual Domain is support for the HP Smart Array P800 controller (single
initiator only)
NOTE:
NOTE:NOTE:
NOTE:
The HP Smart Array P600 supports the cascading of shelves in a 1+3
configuration to allow a maximum of 48 drives in an 8U configuration behind or the
HP Smart Array P600 controller as the P600 has only a single external port.
NOTE:
NOTE:NOTE:
NOTE:
The Smart Array E500 offers RAID 0, 1 and 0+1 and can be upgraded with
ProLiant server to RAID 5 with battery-backed write cache (BBWC) module - 383280-
B21.
NOTE:
NOTE:NOTE:
NOTE:
Smart Arrays P411 and P212 are supported on ProLiant servers only
Smart Array Controllers
Smart Array ControllersSmart Array Controllers
Smart Array Controllers
Supported
SupportedSupported
Supported
(Dual Domain)
HP ProLiant Servers
HP ProLiant ServersHP ProLiant Servers
HP ProLiant Servers
HP Smart Array P800 controller
381513-B21
HP Integrity Servers
HP Integrity ServersHP Integrity Servers
HP Integrity Servers
HP SC44Ge Host Bus Adapter
AH303A
NOTE:
NOTE: NOTE:
NOTE:
Only HP-UX and Open VMS on selected HP Integrity servers supported.
HP Integrity servers that are supported:
rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that
support PCI-e cards).
QuickSpecs
HP 60 Modular Smart Array
HP 60 Modular Smart ArrayHP 60 Modular Smart Array
HP 60 Modular Smart Array
Configuration Information
DA - 12627 North America — Version 37 — June 8, 2011
Page 13