HP (Hewlett-Packard) 418408-B21 Computer Drive User Manual


 
Utilities
UtilitiesUtilities
Utilities
The MSA60 utilizes a single, consistent set of utility software for storage and RAID management, setup,
configuration and troubleshooting. This consistency reduces the cost of ownership by reducing the
training and technical expertise necessary to install and maintain your HP server storage solution.
Configuration Utilities
Configuration UtilitiesConfiguration Utilities
Configuration Utilities
Array Configuration Utility (ACU) [On-line for Microsoft and Linux, Remote Web-Based & Off-line]
Option ROM Configuration for Arrays (ORCA), NetWare ACU CPQONLIN (
only online support no Web
based support
)
Management/Health
Management/HealthManagement/Health
Management/Health
Utilities
UtilitiesUtilities
Utilities
HP Systems Insight Manager
Array Configuration Utility
Array Configuration UtilityArray Configuration Utility
Array Configuration Utility
(ACU)
Provides a graphical view of HP drive array configurations.
Easy to use Wizards for configuration.
Web Based ACU supports On-Line, Remote Web Based and Off-line configuration.
Supports on-line configuration for Microsoft, NetWare and Linux.
HP Systems Insight
HP Systems InsightHP Systems Insight
HP Systems Insight
Manager
ManagerManager
Manager
Powerful storage, server and server option management tool.
Monitor storage from a remote central location.
Browser based Insight Manager 7 provides full access from anywhere on the Intranet, eliminating
the need for a dedicated Insight Manager console.
Supported Operating
Supported OperatingSupported Operating
Supported Operating
Systems
SystemsSystems
Systems
HP ProLiant Servers
HP ProLiant ServersHP ProLiant Servers
HP ProLiant Servers
NOTE:
NOTE:NOTE:
NOTE:
For information on supported Operating Systems, please see the following Smart Array
Quickspecs:
E500:
http://h18004.www1.hp.com/products/quickspecs/12700_na/12700_na.html
P600:
http://h18004.www1.hp.com/products/quickspecs/12247_na/12247_na.html
P800:
http://h18004.www1.hp.com/products/quickspecs/12616_na/12616_na.html
P212:
http://h18004.www1.hp.com/products/quickspecs/13203_na/13203_na.html
P411:
http://h18004.www1.hp.com/products/quickspecs/13202_na/13202_na.html
P812:
http://h18004.www1.hp.com/products/quickspecs/13558_na/13558_na.html
HP Integrity Servers
HP Integrity ServersHP Integrity Servers
HP Integrity Servers
HPUX 11iv2/11iv3
Open VMSV 8.3 1H
NOTE:
NOTE:NOTE:
NOTE:
HPUX 11iv2/11iv3 (for Dual Domain only)
Needs I/O Module (#AG779A), and HP SC44Ge Host Bus Adapter or HP Smart Array P800
Controller
Qualified for the following HP Integrity servers:
rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-
e cards)
NOTE:
NOTE:NOTE:
NOTE:
Open VMS (for Dual Domain only)
Needs I/O Module (#AG779A), and HP (AH303A) SC44Ge Host Bus Adapter
Qualified for the following HP Integrity servers:
rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-
e cards)
QuickSpecs
HP 60 Modular Smart Array
HP 60 Modular Smart ArrayHP 60 Modular Smart Array
HP 60 Modular Smart Array
Software Components
DA - 12627 North America — Version 37 — June 8, 2011
Page 9