HP (Hewlett-Packard) 5697-7483 Switch User Manual


 
Specication
Description
EMC immunity
IEC 61000-4-2 S
everity Level 3 for Electrostatic Discharge
IEC 61000-4-3
Severity Level 3 for Radiated F ields
IEC 61000-4-4
Severity Level 3 for Fast Tr ansients
IEC 61000-4-5
Severity Level 3 for Sur ge Voltage
IEC 61000-4-
6 Conducted Emissions
IEC 61000-4-
11 Voltage Variations
EN 61000-4-
12 Oscillatory Waves Immunity
EN 61000-3-
2 Limits for Harmonic Current Emissions
EN 61000-3
-3 JEIDA
Sy stem ar chitecture Nonblocking shared-memory switch
ANSI protocol FC-PH (FC Physical and Signalling Interface standard)
Modes of operation
FC Class 2, Class 3, and Class F
Maximum fra me size
2112-byte
Port-to-port latency
Less than 2 micr oseconds with no contention (destination
port is free)
Weight and physical dimensions
nl
Table 19 l
ists physical properties.
Table 19 8Gb SAN Switch physical dimensions
Dimensio n
Measurement
Height
29.3 mm (1.15 in)
Width
208 mm (8.19 in)
Depth
280mm(11.02in)
Weight 1.2 7 kg (2 .8 lb)
Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions beyond those
for whic h it was tested. T he ranges specied in Table 20 list the acceptable environment for both
operating and nonoperating conditions.
Table 20 Environmental requirements
Condition Acceptable range during operation
Acceptable range during
non-operation
Ambient
temperature
104°F/40 °C at sea level, derated 1 C
per 1000 ft above sea level
-40°Cto70°Cwithmaximumrateof
change of 20 C /hr
Humidity
5% to 90% relative humidity,
non-condensing
50%to80%relativehumidity,
non-condensing
Altitude
0to10,000ft(3km)abovesealevel 0to40,000ft(12km)abovesealevel
Shock 40 G, 2mS duration
14 0 G, 2 mS ,
Vibration
0.5G,10500Hz 2.0G,5500Hz
Airow 4 7 cubic ft/minute
None required
50
SAN Switch technical specications