HP (Hewlett-Packard) 6100 Network Router User Manual


 
EVA Starter Kits, EVA4100
EVA6100 EVA8100
Controller Model
HSV200-B HSV200-B HSV210-B
Controller Cache
4 GB per controller pair standard 4 GB per controller pair standard 8 GB per controller pair standard
Battery Backup for Cache
Yes, up to 96 hours Yes, up to 96 hours Yes, up to 96 hours
Virtual Controller Software
(VCS)
HP StorageWorks
EVA4x00/6x00/8x00 XCS
v6.110
HP StorageWorks
EVA4x00/6x00/8x00 XCS
v6.110
HP StorageWorks
EVA4x00/6x00/8x00 XCS
v6.110
Host Interface
Fibre Channel Switched Fabric Fibre Channel Switched Fabric Fibre Channel Switched Fabric
Host Ports per Controller
Dual 4Gb/s FC enabled (running
at 2 or 4 Gb/s with 2 or 4 Gb/s
switches and HBAs)
Dual 4Gb/s FC enabled (running
at 2 or 4 Gb/s with 2 or 4 Gb/s
switches and HBAs)
Four
4Gb/s FC enabled (running
at 2 or 4 Gb/s with 2 or 4 Gb/s
switches and HBAs)
Drive Interface
Two 2Gb/s FC-AL ports per
controller in redundant pairs, two
paths to each dual ported HDD
Two 2Gb/s FC-AL ports per
controller in redundant pairs, two
paths to each dual ported HDD
Four 2Gb/s FC-AL ports per
controller in redundant pairs, two
paths to each dual ported HDD
RAID Levels
Vraid0, Vraid1, Vraid5 & Cross
Vraid Snaps
Vraid0, Vraid1, Vraid5 & Cross
Vraid Snaps
Vraid0, Vraid1, Vraid5 & Cross
Vraid Snaps
Maximum Disks
Supported
56 per Controller Pair
112 per Controller Pair
240 per Controller Pair (168 in
one cabinet, expandable to 240
with an optional expansion
cabinet.)
JBOD Support
(behind XP)
Yes Yes Yes
Fibre Channel Switches &
Directors
Optical Switches and Directors:
http://h18006.www1.hp.com/storage/saninfrastructure/switches.html
O/S Support
HP-UX
HP OpenVMS
HP Tru64 UNIX
Windows XP Professional
Windows 2000 Server & Advanced Server
Windows 2003 Standard/Enterprise (32/64-bit) and Extended/DataCenter (64-bit)
Sun Solaris
Linux
IBM AIX
Novell NetWare
VMware
Apple Mac OSX
NOTE:
See Operating System, Cluster and High Availability Compatibility matrix above for Operating
System version detail.
Sustained I/O and MB
Throughput
Greater than 154,000 and over
1380 MB/s
Greater than 154,000 and over
1380 MB/s
Greater than 225,000 and over
2450 MB/s
Redundant Blowers
Yes Yes Yes
Environmental Monitoring
Unit
Yes. Monitors Power and
Temperature
Yes. Monitors Power and
Temperature
Yes. Monitors Power and
Temperature
Regulatory approvals
UL, CSA, TUV, FCC, CE MARK,
CTICK, BSMI, VCCI
UL, CSA, TUV, FCC, CE MARK,
CTICK, BSMI, VCCI
UL, CSA, TUV, FCC, CE MARK,
CTICK, BSMI, VCCI
QuickSpecs
HP StorageWorks Enterprise Virtual Array Family
Technical Specifications
DA - 12745 Worldwide QuickSpecs — Version 5 — 2.26.2008
Page 47