HP (Hewlett-Packard) 6100 Network Router User Manual


 
Management Software
Command View EVA v7.0 or v8.0 used with the Storage Management Appliance software v2.1 running
on the HP OpenView Storage Management Appliance (SMA) or with a server in the SAN running
Microsoft Windows.
Disk Drives, Interface
Dual-port 2/4 Gb/s FC-AL Dual-port 2/4 Gb/s FC-AL Dual-port 2/4 Gb/s FC-AL
Disk Drives Enclosure
14 bay switched enclosure 14 bay switched enclosure 14 bay switched enclosure
NOTE:
EVA4100 Starter Kits comes pre-configured with a 2C1D, 8-146GB 15K or 300GB 10K rpm HDDs Command View EVA
software with licensing up to 4TBs. The EVA4100 Starter Kit for HP BladeSystems comes pre-configured with a 2C1D and Command
View software with licensing up to 4TB's.
EVA4100 EVA6100 EVA8100
Operating Temperature
50° to 95° F (10° to 35° C) - Reduce rating by 1° F for each 1000 ft altitude (1.8° C/1,000 m)
Shipping Temperature
-40° to 150° F (-40° to 66° C)
Humidity
10% to 90% non-condensing
Shipping Humidity
5% to 90% non-condensing
Altitude
Up to 8,000 ft (2,400 m)
Air Quality
Not to exceed 500,000 particles per cubic foot of air at a size of 0.5 micron or larger
Power Data
(North America/Europe/Japan)
maximum configuration
EVA4100 EVA6100 EVA8100
AC plug type
(quantity 2)
North America-3 wire NEMA No. L6-30P, 30 Amp (208 to 240V, 50-60Hz 30A)
Europe - 3 wire, 2 pole IEC 309, 30 amp, (220 to 240V 50Hz 32A)
Number of phases
Single
Rated current
17A @ 200V-240V AC, 60Hz total, 4.25 A per power cord
Nominal Line Voltage
North America - 208 or 230V
Europe - 230V
Japan - 206V
Range Line Voltage
187 to 256V
Line Frequency
North America 60Hz, Europe 50Hz, Japan 50 or 60 Hz
Enterprise Virtual Array 4100 and 4100 Starter Kits
NOTE:
This data represents fully populated
drive shelves with 15K rpm disk drives. Other
drive types may vary slightly.
208 Volts 230 Volts
2C1D 2C2D 2C3D 2C4D 2C1D 2C2D 2C3D 2C4D
Typical
Total System Wattage
638 1013 1390 1767 638 1013 1390 1767
Total System BTU/hour
1729 3014 4300 5585 1729 3014 4300 5585
Input Current (A) -
Typical per system
1.6 2.6 3.5 4.4 1.5 2.4 3.3 4.2
In Rush Current (A)
98 132 170 220 104 147 190 244
Failover Mode
Input Current (A) -
Maximum per system
2.7 4.3 5.9 7.5 2.6 4.1 5.5 7.1
NOTE:
Typical is described as a system in normal steady state operation. (I.e., both PDUs operating normally, the array
reading/writing to disk drives in a production environment)
QuickSpecs
HP StorageWorks Enterprise Virtual Array Family
Technical Specifications
DA - 12745 Worldwide QuickSpecs — Version 5 — 2.26.2008
Page 48