HP (Hewlett-Packard) 670857-S01 Server User Manual


 
Cabling 94
o
Hard drive status LEDs are not supported.
o Hard drive thermal status monitoring is not supported.
o Hot-plug operation is not supported.
Because only one drive bay is enabled, all remaining drives can be removed.
For proper thermal cooling, install blanks in all bays that do not have a drive installed. Order a sufficient
number of 6.35-cm (2.5-in) or 8.89-cm (3.5-in) hard drive blank option kits from an HP authorized
reseller. For more information, see the server maintenance and service guide.
The standard SATA driver is included with supported operating systems. No additional driver is
required.
To install the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend the server from the rack (on page 23).
4. Remove the access panel (on page 24).
WARNING: Eliminate the risk of electric shock by removing all AC power from the system before
installing or replacing any non-hot-plug hardware option. Disconnect all power cords to
completely remove power from the server.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
IMPORTANT: It is necessary to remove the PCI riser cage only if there is a full-length expansion
board installed.
5. Release the full-length expansion board retainer, and then remove the PCI riser cage.
6. Remove the air baffle (on page 32).
7. Remove the fan cage.